Solar radiation model
LT Wong, WK Chow
Applied energy 69 (3), 191-224, 2001
5632001
A multivariate-logistic model for acceptance of indoor environmental quality (IEQ) in offices
LT Wong, KW Mui, PS Hui
Building and environment 43 (1), 1-6, 2008
3712008
An evaluation model for indoor environmental quality (IEQ) acceptance in residential buildings
ACK Lai, KW Mui, LT Wong, LY Law
Energy and buildings 41 (9), 930-936, 2009
3452009
Student learning performance and indoor environmental quality (IEQ) in air-conditioned university teaching rooms
MC Lee, KW Mui, LT Wong, WY Chan, EWM Lee, CT Cheung
Building and Environment 49, 238-244, 2012
2882012
Shower water heat recovery in high-rise residential buildings of Hong Kong
LT Wong, KW Mui, Y Guan
Applied Energy 87 (2), 703-709, 2010
2042010
A statistical model for characterizing common air pollutants in air-conditioned offices
LT Wong, KW Mui, PS Hui
Atmospheric Environment 40 (23), 4246-4257, 2006
1182006
Numerical modeling of exhaled droplet nuclei dispersion and mixing in indoor environments
KW Mui, LT Wong, CL Wu, ACK Lai
Journal of hazardous materials 167 (1-3), 736-744, 2009
1052009
A field survey of the expected desirable thermal environment for older people
LT Wong, KNK Fong, KW Mui, WWY Wong, LW Lee
Indoor and built environment 18 (4), 336-345, 2009
1012009
Neutral temperature in subtropical climates—a field survey in air-conditioned offices
KW Mui, LT Wong
Building and Environment 42 (2), 699-706, 2007
962007
Modeling water consumption and flow rates for flushing water systems in high-rise residential buildings in Hong Kong
LT Wong, KW Mui
Building and Environment 42 (5), 2024-2034, 2007
802007
Experimental study on visibility of exit signs in buildings
LT Wong, KC Lo
Building and environment 42 (4), 1836-1842, 2007
802007
Cooling load calculations in subtropical climate
KW Mui, LT Wong
Building and Environment 42 (7), 2498-2504, 2007
722007
An energy benchmarking model for ventilation systems of air-conditioned offices in subtropical climates
KW Mui, LT Wong, LY Law
Applied Energy 84 (1), 89-98, 2007
652007
A numerical study of ventilation strategies for infection risk mitigation in general inpatient wards
MK Satheesan, KW Mui, LT Wong
Building simulation 13, 887-896, 2020
642020
Ventilation of general hospital wards for mitigating infection risks of three kinds of viruses including Middle East respiratory syndrome coronavirus
HC Yu, KW Mui, LT Wong, HS Chu
Indoor and Built Environment 26 (4), 514-527, 2017
572017
Energy efficiency of elevated water supply tanks for high-rise buildings
CT Cheung, KW Mui, LT Wong
Applied energy 103, 685-691, 2013
542013
Feasibility study of an express assessment protocol for the indoor air quality of air-conditioned offices
PS Hui, LT Wong, KW Mui
Indoor and Built Environment 15 (4), 373-378, 2006
522006
Acceptable illumination levels for office occupants
KW Mui, LT Wong
Architectural Science Review 49 (2), 116-119, 2006
522006
Preliminary studies on a new method for assessing ventilation in large spaces
WK Chow, WY Fung, LT Wong
Building and Environment 37 (2), 145-152, 2002
512002
An energy performance assessment for indoor environmental quality (IEQ) acceptance in air-conditioned offices
LT Wong, KW Mui
Energy Conversion and Management 50 (5), 1362-1367, 2009