Follow
Joseph Firrantello
Joseph Firrantello
Senior Building Energy Engineer, McKinstry
Verified email at mckinstry.com
Title
Cited by
Cited by
Year
Case studies of building envelope leakage measurement using an air-handler fan pressurisation approach
JW Jeong, J Firrantello, WP Bahnfleth, JD Freihaut, A Musser
Building Services Engineering Research and Technology 29 (2), 137-155, 2008
362008
Effectiveness of an ultraviolet germicidal irradiation system in enhancing cooling coil energy performance in a hot and humid climate
Y Wang, C Sekhar, WP Bahnfleth, KW Cheong, J Firrantello
Energy and Buildings 130, 321-329, 2016
212016
Use of Factorial Sensitivity Analysis in Multizone Airflow Model Tuning.
J Firrantello, WP Bahnfleth, A Musser, JD Freihaut, JW Jeong
ASHRAE Transactions 113 (1), 2007
122007
Field measurement and modeling of UVC cooling coil irradiation for HVAC energy use reduction (RP-1738)–Part 2: Energy, indoor air quality, and economic modeling
J Firrantello, W Bahnfleth
Science and Technology for the Built Environment, 2017
9*2017
Effects of HVAC system and building characteristics on exposure of occupants to short-duration point source aerosol releases
JT Firrantello, P Aumpansub, WP Bahnfleth, B Hu, JD Freihaut, B Thran, ...
Journal of architectural engineering 13 (2), 84-94, 2007
92007
Field measurement and modeling of UVC cooling coil irradiation for heating, ventilating, and air conditioning energy use reduction (RP-1738)—Part 1: Field measurements
J Firrantello, W Bahnfleth, P Kremer
Science and Technology for the Built Environment 24 (6), 588-599, 2018
72018
Feasibility of wireless measurements for semi-empirical multizone airflow model tuning
JW Jeong, J Firrantello, JD Freihaut, WP Bahnfleth, A Musser
Building and environment 43 (9), 1507-1520, 2008
72008
Application of sensitivity analysis to multizone airflow model tuning
J Firrantello, W Bahnfleth, A Musser, J Freihaut, JW Jeong
8th REHVA World Congress, CLIMA, 2005
72005
Field study of energy use-related effects of ultraviolet germicidal irradiation of a cooling coil
J Firrantello, WP Bahnfleth, R Montgomery, P Kremer
ASHRAE Transactions 122 (1), 8, 2016
62016
Field testing of data driven multizone model calibration procedure
J Firrantello, W Bahnfleth, JW Jeong, A Musser, J Freihaut
Clima 2007 WellBeing Indoors, Helsinki, Finland, June 10 14, 2007
62007
Simulation and monetization of collateral airborne infection risk improvements from ultraviolet germicidal irradiation for coil maintenance
J Firrantello, W Bahnfleth
Science and Technology for the Built Environment 24 (2), 135-148, 2018
52018
Effects of an ultraviolet coil irradiation system on the airside heat transfer coefficient and low ΔT syndrome in a hot and humid climate
Y Wang, C Sekhar, WP Bahnfleth, KW Cheong, J Firrantello
Science and Technology for the Built Environment 23 (4), 582-593, 2017
42017
Comparison of semi-quantitative and formal metrics for multi-zone airflow model quality assessment
WP Bahnfleth, P Saekow, J Firrantello, PA Kremer
HVAC&R Research 18 (1-2), 252-263, 2012
42012
Development of a Rapid, Data Driven Method for Tuning Multizone Airflow Models
JT Firrantello
Pennsylvania State University, 2007
32007
Energy and Economic Impacts of Ultraviolet Germicidal Irradiation of Cooling Coils
JT Firrantello
12016
A methodology for assessing energy use and effectiveness of UVGI systems
JW DeGraw, JT Firrantello, WP Bahnfleth
10th International Conference on Healthy Buildings 2012, 316-321, 2012
12012
An air cleaner effectiveness approach to the analysis of in-duct UVGI systems
J Firrantello, W Bahnfleth
12th International Conference on Indoor Air Quality and Climate 2011, 1582-1587, 2011
2011
Does an AHU-installed UVGI System Enhance the Heat and Mass Transfer Performance of a Cooling Coil in a Hot and Humid Climate?
Y Wang, C Sekhar, WP Bahnfleth, KW Cheong, J Firrantello
The system can't perform the operation now. Try again later.