Omer T. Inan
TitleCited byYear
Toward ubiquitous blood pressure monitoring via pulse transit time: theory and practice
R Mukkamala, JO Hahn, OT Inan, LK Mestha, CS Kim, H Töreyin, S Kyal
IEEE Transactions on Biomedical Engineering 62 (8), 1879-1901, 2015
3432015
Robust neural-network-based classification of premature ventricular contractions using wavelet transform and timing interval features
OT Inan, L Giovangrandi, GTA Kovacs
IEEE transactions on Biomedical Engineering 53 (12), 2507-2515, 2006
3162006
Ballistocardiography and seismocardiography: A review of recent advances
OT Inan, PF Migeotte, KS Park, M Etemadi, K Tavakolian, R Casanella, ...
IEEE journal of biomedical and health informatics 19 (4), 1414-1427, 2014
2912014
Robust ballistocardiogram acquisition for home monitoring
OT Inan, M Etemadi, RM Wiard, L Giovangrandi, GTA Kovacs
Physiological measurement 30 (2), 169, 2009
2092009
Ballistocardiography—a method worth revisiting
L Giovangrandi, OT Inan, RM Wiard, M Etemadi, GTA Kovacs
2011 annual international conference of the IEEE engineering in medicine and …, 2011
1242011
Non-invasive cardiac output trending during exercise recovery on a bathroom-scale-based ballistocardiograph
OT Inan, M Etemadi, A Paloma, L Giovangrandi, GTA Kovacs
Physiological measurement 30 (3), 261, 2009
882009
Systems and methods for monitoring heart function
OT Inan, M Etemadi, LB Giovangrandi, GT Kovacs, RM Wiard
US Patent 8,870,780, 2014
832014
Rapid assessment of cardiac contractility on a home bathroom scale
M Etemadi, OT Inan, L Giovangrandi, GTA Kovacs
IEEE transactions on information technology in biomedicine 15 (6), 864-869, 2011
832011
Ballistocardiogram as proximal timing reference for pulse transit time measurement: Potential for cuffless blood pressure monitoring
CS Kim, AM Carek, R Mukkamala, OT Inan, JO Hahn
IEEE Transactions on Biomedical Engineering 62 (11), 2657-2664, 2015
792015
Extracting respiratory information from seismocardiogram signals acquired on the chest using a miniature accelerometer
K Pandia, OT Inan, GTA Kovacs, L Giovangrandi
Physiological measurement 33 (10), 1643, 2012
612012
Ballistocardiogram: Mechanism and potential for unobtrusive cardiovascular health monitoring
CS Kim, SL Ober, MS McMurtry, BA Finegan, OT Inan, R Mukkamala, ...
Scientific reports 6, 31297, 2016
602016
Weighing scale-based pulse transit time is a superior marker of blood pressure than conventional pulse arrival time
SLO Martin, AM Carek, CS Kim, H Ashouri, OT Inan, JO Hahn, ...
Scientific reports 6, 39273, 2016
582016
Noninvasive measurement of physiological signals on a modified home bathroom scale
OT Inan, D Park, L Giovangrandi, GTA Kovacs
IEEE Transactions on Biomedical Engineering 59 (8), 2137-2143, 2012
522012
Toward continuous, noninvasive assessment of ventricular function and hemodynamics: Wearable ballistocardiography
AD Wiens, M Etemadi, S Roy, L Klein, OT Inan
IEEE journal of biomedical and health informatics 19 (4), 1435-1442, 2014
512014
Novel methods for estimating the ballistocardiogram signal using a simultaneously acquired electrocardiogram
OT Inan, M Etemadi, RM Wiard, GTA Kovacs, L Giovangrandi
2009 Annual International Conference of the IEEE Engineering in Medicine and …, 2009
482009
Automatic detection of motion artifacts in the ballistocardiogram measured on a modified bathroom scale
RM Wiard, OT Inan, B Argyres, M Etemadi, GTA Kovacs, L Giovangrandi
Medical & biological engineering & computing 49 (2), 213-220, 2011
472011
Adaptive cancellation of floor vibrations in standing ballistocardiogram measurements using a seismic sensor as a noise reference
OT Inan, M Etemadi, B Widrow, GTA Kovacs
IEEE Transactions on Biomedical Engineering 57 (3), 722-727, 2010
472010
A wearable patch to enable long-term monitoring of environmental, activity and hemodynamics variables
M Etemadi, OT Inan, JA Heller, S Hersek, L Klein, S Roy
IEEE transactions on biomedical circuits and systems 10 (2), 280-288, 2015
462015
Novel methods for sensing acoustical emissions from the knee for wearable joint health assessment
CN Teague, S Hersek, H Töreyin, ML Millard-Stafford, ML Jones, ...
IEEE Transactions on Biomedical Engineering 63 (8), 1581-1590, 2016
402016
Evaluating the lower-body electromyogram signal acquired from the feet as a noise reference for standing ballistocardiogram measurements
OT Inan, GTA Kovacs, L Giovangrandi
IEEE Transactions on Information Technology in Biomedicine 14 (5), 1188-1196, 2010
402010
The system can't perform the operation now. Try again later.
Articles 1–20