Follow
Jose Lipovetzky
Jose Lipovetzky
Centro Atómico Bariloche - CNEA / CONICET
Verified email at fi.uba.ar - Homepage
Title
Cited by
Cited by
Year
Particle detection and classification using commercial off the shelf CMOS image sensors
M Pérez, J Lipovetzky, MS Haro, I Sidelnik, JJ Blostein, FA Bessia, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2016
572016
Analysis of SRAM-based FPGA SEU sensitivity to combined EMI and TID-imprinted effects
J Benfica, B Green, BC Porcher, LB Poehls, F Vargas, NH Medina, ...
IEEE Transactions on Nuclear Science 63 (2), 1294-1300, 2016
432016
Extension of the measurement range of MOS dosimeters using radiation induced charge neutralization
A Faigón, J Lipovetzky, E Redin, G Krusczenski
IEEE Transactions on Nuclear Science 55 (4), 2141-2147, 2008
372008
The oscura experiment
A Aguilar-Arevalo, FA Bessia, N Avalos, D Baxter, X Bertou, C Bonifazi, ...
arXiv preprint arXiv:2202.10518, 2022
312022
Field oxide n-channel mos dosimeters fabricated in cmos processes
J Lipovetzky, MA García-Inza, S Carbonetto, MJ Carra, E Redin, ...
IEEE Transactions on Nuclear Science 60 (6), 4683-4691, 2013
312013
Electrically erasable metal–oxide–semiconductor dosimeters
J Lipovetzky, EG Redin, A Faigon
IEEE Transactions on Nuclear Science 54 (4), 1244-1250, 2007
312007
Zero temperature coefficient bias in MOS devices. Dependence on interface traps density, application to MOS dosimetry
SH Carbonetto, MAG Inza, J Lipovetzky, EG Redin, LS Salomone, ...
IEEE Transactions on Nuclear Science 58 (6), 3348-3353, 2011
272011
Soft X-rays spectroscopy with a commercial CMOS image sensor at room temperature
MS Haro, FA Bessia, M Pérez, JJ Blostein, DF Balmaceda, MG Berisso, ...
Radiation Physics and Chemistry 167, 108354, 2020
252020
Switched bias differential MOSFET dosimeter
M Garcia-Inza, S Carbonetto, J Lipovetzky, MJ Carra, LS Salomone, ...
IEEE Transactions on Nuclear Science 61 (3), 1407-1413, 2014
222014
Reducing measurement uncertainties using bias cycled measurement in MOS dosimetry at different temperatures
J Lipovetzky, EG Redin, MAG Inza, S Carbonetto, A Faigon
IEEE Transactions on Nuclear Science 57 (2), 848-853, 2010
222010
X‐ray micrographic imaging system based on COTS CMOS sensors
F Alcalde Bessia, M Pérez, J Lipovetzky, NA Piunno, H Mateos, I Sidelnik, ...
International Journal of Circuit Theory and Applications 46 (10), 1848-1857, 2018
202018
Commercial CMOS pixel array for beta and gamma radiation particle counting
M Pérez, MS Haro, I Sidelnik, L Tozzi, DR Brito, C Mora, JJ Blostein, ...
2015 Argentine School of Micro-Nanoelectronics, Technology and Applications …, 2015
202015
Displacement damage in cmos image sensors after thermal neutron irradiation
FA Bessia, M Pérez, MS Haro, I Sidelnik, JJ Blostein, S Suárez, P Pérez, ...
IEEE Transactions on Nuclear Science 65 (11), 2793-2801, 2018
172018
Thermal neutron detector based on cots cmos imagers and a conversion layer containing gadolinium
M Pérez, JJ Blostein, FA Bessia, A Tartaglione, I Sidelnik, MS Haro, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2018
172018
Experimental evidence and modeling of two types of electron traps in Al2O3 for nonvolatile memory applications
L Sambuco Salomone, J Lipovetzky, SH Carbonetto, G Inza, EG Redin, ...
Journal of Applied Physics 113 (7), 2013
172013
Floating gate PMOS dosimeters under bias controlled cycled measurement
MG Inza, J Lipovetzky, EG Redin, S Carbonetto, A Faigon
IEEE Transactions on Nuclear Science 58 (3), 808-812, 2011
172011
CMOS differential and amplified dosimeter with field oxide N-channel MOSFETs
S Carbonetto, M Garcia-Inza, J Lipovetzky, MJ Carra, E Redin, ...
IEEE Transactions on Nuclear Science 61 (6), 3466-3471, 2014
152014
Multi-spectral x-ray transmission imaging using a bsi cmos image sensor
J Lipovetzky, A Cicuttin, ML Crespo, MS Haro, FA Bessia, M Pérez, ...
Radiation Physics and Chemistry 167, 108244, 2020
142020
Radiation sensor based on MOSFETs mismatch amplification for radiotherapy applications
M Garcia-Inza, SH Carbonetto, J Lipovetzky, A Faigon
IEEE Transactions on Nuclear Science 63 (3), 1784-1789, 2016
142016
New fowler-nordheim injection, charge neutralization, and gamma tests on the REM RFT300 RADFET dosimeter
J Lipovetzky, A Holmes-Siedle, MG Inza, S Carbonetto, E Redin, A Faigon
IEEE Transactions on Nuclear Science 59 (6), 3133-3140, 2012
122012
The system can't perform the operation now. Try again later.