Follow
Tim Boretius
Tim Boretius
neuroloop GmbH
Verified email at ieee.org
Title
Cited by
Cited by
Year
Restoring Natural Sensory Feedback in Real-Time Bidirectional Hand Prostheses
S Raspopovic, M Capogrosso, FM Petrini, M Bonizzato, J Rigosa, ...
Science Translational Medicine 6 (222), 222ra19-222ra19, 2014
10932014
Polymers for neural implants
C Hassler, T Boretius, T Stieglitz
Journal of Polymer Science Part B: Polymer Physics 49 (1), 18-33, 2011
6082011
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
T Boretius, J Badia, A Pascual-Font, M Schuettler, X Navarro, K Yoshida, ...
Biosensors and Bioelectronics 26 (1), 62-69, 2010
5062010
Comparative analysis of transverse intrafascicular multichannel, longitudinal intrafascicular and multipolar cuff electrodes for the selective stimulation of nerve fascicles
J Badia, T Boretius, D Andreu, C Azevedo-Coste, T Stieglitz, X Navarro
Journal of neural engineering 8 (3), 036023, 2011
2592011
Thin films and microelectrode arrays for neuroprosthetics
J Ordonez, M Schuettler, C Boehler, T Boretius, T Stieglitz
MRS bulletin 37 (06), 590-598, 2012
1362012
Biocompatibility of chronically implanted transverse intrafascicular multichannel electrode (TIME) in the rat sciatic nerve
J Badia, T Boretius, A Pascual-Font, E Udina, T Stieglitz, X Navarro
Biomedical Engineering, IEEE Transactions on 58 (8), 2324-2332, 2011
1202011
Stimulation Selectivity of the ‘Thin-Film Longitudinal Intrafascicular Electrode’(tfLIFE) and the 'Transverse Intrafascicular Multi-Channel Electrode'(TIME) in the Large Nerve …
A Kundu, K Harreby, K Yoshida, T Boretius, T Stieglitz, W Jensen
Transactions on Neural Systems and Rehabilitation Engineering, 1-1, 2013
842013
On the Stability of Poly‐Ethylenedioxythiopene as Coating Material for Active Neural Implants
T Boretius, M Schuettler, T Stieglitz
Artificial Organs 35 (3), 245-248, 2011
612011
A transverse intrafascicular multichannel electrode (TIME) to treat phantom limb pain—Towards human clinical trials
T Boretius, K Yoshida, J Badia, K Harreby, A Kundu, X Navarro, W Jensen, ...
2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and …, 2012
502012
Stability of flexible thin-film metallization stimulation electrodes: analysis of explants after first-in-human study and improvement of in vivo performance
P Čvančara, T Boretius, VM López-Álvarez, P Maciejasz, D Andreu, ...
Journal of neural engineering 17 (4), 046006, 2020
492020
Subchronic stimulation performance of transverse intrafascicular multichannel electrodes in the median nerve of the Göttingen minipig
KR Harreby, A Kundu, K Yoshida, T Boretius, T Stieglitz, W Jensen
Artificial organs 39 (2), E36-E48, 2015
282015
Delaying discharge after the stimulus significantly decreases muscle activation thresholds with small impact on the selectivity: an in vivo study using TIME
P Maciejasz, J Badia, T Boretius, D Andreu, T Stieglitz, W Jensen, ...
Medical & biological engineering & computing 53 (4), 371-379, 2015
232015
High-porous platinum electrodes for functional electrical stimulation
T Boretius, T Jurzinsky, C Koehler, S Kerzenmacher, H Hillebrecht, ...
2011 Annual International Conference of the IEEE Engineering in Medicine and …, 2011
222011
Evaluation of polyimide as substrate material for electrodes to interface the peripheral nervous system
T Stieglitz, M Schuettler, B Rubehn, T Boretius, J Badia, X Navarro
2011 5th International IEEE/EMBS Conference on Neural Engineering, 529-533, 2011
212011
Development of a neurotechnological system for relieving phantom limb pain using transverse intrafascicular electrodes (TIME)
T Stieglitz, T Boretius, X Navarro, J Badia, D Guiraud, JL Divoux, S Micera, ...
Biomedizinische Technik/Biomedical Engineering 57 (6), 457-465, 2012
172012
Electrical characterization of platinum, stainless steel and platinum/iridium as electrode materials for a new neural interface
C Henle, W Meier, M Schuettler, T Boretius, T Stieglitz
World Congress on Medical Physics and Biomedical Engineering, September 7-12 …, 2009
122009
TIME: A Transverse Intrafascicular Multichannel Electrode
T Boretius
Der Andere Verlag, 2013
82013
Miniaturized neural interfaces and implants
T Stieglitz, T Boretius, J Ordonez, C Hassler, C Henle, W Meier, ...
Microfluidics, BioMEMS, and Medical Microsystems X 8251, 82510A, 2012
82012
Preliminary investigations on laminin coatings for flexible polyimide/platinum thin films for PNS applications
S Bossi, A Benvenuto, P Wieringa, G Di Pino, E Guglielmelli, T Boretius, ...
Engineering in Medicine and Biology Society (EMBC), 2010 Annual …, 2010
82010
Dependence of implantation angle of the transverse, intrafascicular electrode (TIME) on selective activation of pig forelimb muscles
A Kundu, W Jensen, M Kurstjens, T Stieglitz, T Boretius, K Yoshida
Vienna International Workshop on Functional Electrical Stimulation, 315-317, 2010
82010
The system can't perform the operation now. Try again later.
Articles 1–20