J°rn Toftum
J°rn Toftum
Unknown affiliation
No verified email
Title
Cited by
Cited by
Year
Handbook of human factors and ergonomics methods
NA Stanton, A Hedge, K Brookhuis, E Salas, HW Hendrick
CRC press, 2004
7692004
Extension of the PMV model to non-air-conditioned buildings in warm climates
PO Fanger, J Toftum
Energy and buildings 34 (6), 533-536, 2002
7142002
Progress in thermal comfort research over the last twenty years
RJ de Dear, T Akimoto, EA Arens, G Brager, C Candido, KWD Cheong, ...
Indoor air 23 (6), 442-461, 2013
3602013
Window opening behaviour modelled from measurements in Danish dwellings
R Andersen, V Fabi, J Toftum, SP Corgnati, BW Olesen
Building and environment 69, 101-113, 2013
2172013
Upper limits of air humidity for preventing warm respiratory discomfort
J Toftum, AS J°rgensen, PO Fanger
Energy and Buildings 28 (1), 15-23, 1998
2101998
Differences between young adults and elderly in thermal comfort, productivity, and thermal physiology in response to a moderate temperature drift and a steady‐state condition
L Schellen, WD van Marken Lichtenbelt, MGLC Loomans, J Toftum, ...
Indoor air 20 (4), 273-283, 2010
2032010
Children’s phthalate intakes and resultant cumulative exposures estimated from urine compared with estimates from dust ingestion, inhalation and dermal absorption in theirá…
G Bek÷, CJ Weschler, S Langer, M Callesen, J Toftum, G Clausen
PloS one 8 (4), e62442, 2013
1962013
Phthalate and PAH concentrations in dust collected from Danish homes and daycare centers
S Langer, CJ Weschler, A Fischer, G Bek÷, J Toftum, G Clausen
Atmospheric Environment 44 (19), 2294-2301, 2010
1922010
Upper limits for indoor air humidity to avoid uncomfortably humid skin
J Toftum, AS J°rgensen, PO Fanger
Energy and Buildings 28 (1), 1-13, 1998
1711998
Ventilation rates in the bedrooms of 500 Danish children
G Bek÷, T Lund, F Nors, J Toftum, G Clausen
Building and Environment 45 (10), 2289-2295, 2010
1692010
Air movement--good or bad?
J Toftum
Indoor air 14, 40-45, 2004
1582004
Phthalate metabolites in urine samples from Danish children and correlations with phthalates in dust samples from their homes and daycare centers
S Langer, G Bek÷, CJ Weschler, LM Brive, J Toftum, M Callesen, ...
International journal of hygiene and environmental health 217 (1), 78-87, 2014
134*2014
Transdermal Uptake of Diethyl Phthalate and Di(n-butyl) Phthalate Directly from Air: Experimental Verification
CJ Weschler, G Bek÷, HM Koch, T Salthammer, T Schripp, J Toftum, ...
Environmental health perspectives 123 (10), 928-934, 2015
1202015
A Bayesian Network approach to the evaluation of building design and its consequences for employee performance and operational costs
KL Jensen, J Toftum, P Friis-Hansen
Building and Environment 44 (3), 456-462, 2009
1022009
Central automatic control or distributed occupant control for better indoor environment quality in the future
J Toftum
Building and environment 45 (1), 23-28, 2010
972010
Development of the ASHRAE global thermal comfort database II
VF Ličina, T Cheung, H Zhang, R De Dear, T Parkinson, E Arens, C Chun, ...
Building and Environment 142, 502-512, 2018
942018
Draught sensitivity is influenced by general thermal sensation
J Toftum, R Nielsen
International Journal of Industrial Ergonomics 18 (4), 295-305, 1996
941996
Human response to combined indoor environment exposures
J Toftum
Energy and buildings 34 (6), 601-606, 2002
922002
Role of clothing in both accelerating and impeding dermal absorption of airborne SVOCs
GC Morrison, CJ Weschler, G Bek÷, HM Koch, T Salthammer, T Schripp, ...
Journal of exposure science & environmental epidemiology 26 (1), 113-118, 2016
892016
Occupant performance and building energy consumption with different philosophies of determining acceptable thermal conditions
J Toftum, RV Andersen, KL Jensen
Building and Environment 44 (10), 2009
892009
The system can't perform the operation now. Try again later.
Articles 1–20