Thermal comfort, perceived air quality, and cognitive performance when personally controlled air movement is used by tropically acclimatized persons S Schiavon, B Yang, Y Donner, VWC Chang, WW Nazaroff Indoor air 27 (3), 690-702, 2017 | 154 | 2017 |
A review of advanced air distribution methods - theory, practice, limitations and solutions B Yang, A Melikov, A Kabanshi, C Zhang, F Bauman, G Cao, H Awbi, ... Energy and Buildings 202, 109359, 2019 | 138 | 2019 |
Outdoor thermal comfort under subarctic climate of north Sweden–A pilot study in Umeå B Yang, T Olofsson, G Nair, A Kabanshi Sustainable cities and society 28, 387-397, 2017 | 120 | 2017 |
Ceiling mounted personalized ventilation system in hot and humid climate—An energy analysis B Yang, C Sekhar, AK Melikov Energy and Buildings 42 (12), 2304-2308, 2010 | 102 | 2010 |
Non-invasive (non-contact) measurements of human thermal physiology signals and thermal comfort/discomfort poses -A review B Yang, X Li, Y Hou, A Meier, X Cheng, JH Choi, F Wang, H Wang, ... Energy and Buildings 224, 110261, 2020 | 93 | 2020 |
Ceiling‐mounted personalized ventilation system integrated with a secondary air distribution system–a human response study in hot and humid climate B Yang, SC Sekhar, AK Melikov Indoor air 20 (4), 309-319, 2010 | 80 | 2010 |
Simulation of heavy gas dispersion in a large indoor space using CFD model L Dong, H Zuo, L Hu, B Yang, L Li, L Wu Journal of loss prevention in the process industries 46, 1-12, 2017 | 69 | 2017 |
A pilot study of online non-invasive measuring technology based on video magnification to determine skin temperature X Cheng, B Yang, T Olofsson, G Liu, H Li Building and Environment 121, 1-10, 2017 | 56 | 2017 |
Cooling efficiency of a brushless direct current stand fan B Yang, S Schiavon, C Sekhar, D Cheong, KW Tham, WW Nazaroff Building and Environment 85, 196-204, 2015 | 52 | 2015 |
Real-time and contactless measurements of thermal discomfort based on human poses for energy efficient control of buildings B Yang, X Cheng, D Dai, T Olofsson, H Li, A Meier Building and Environment 162, 106284, 2019 | 51 | 2019 |
Performance evaluation of ceiling mounted personalized ventilation system B Yang, A Melikov, C Sekhar ASHRAE transactions 115 (2), 395-407, 2009 | 50 | 2009 |
Particle exposure during the 2013 haze in Singapore: Importance of the built environment J Zhou, A Chen, Q Cao, B Yang, VWC Chang, WW Nazaroff Building and Environment 93, 14-23, 2015 | 49 | 2015 |
NIDL: A pilot study of contactless measurement of skin temperature for intelligent building X Cheng, B Yang, A Hedman, T Olofsson, H Li, LV Gool Energy and Buildings 198, 340-352, 2019 | 48 | 2019 |
An experimental study on a novel radiant-convective heating system based on air source heat pump J Dong, L Zhang, S Deng, B Yang, S Huang Energy and Buildings 158, 812-821, 2018 | 48 | 2018 |
Indoor and outdoor particles in an air-conditioned building during and after the 2013 haze in Singapore A Chen, Q Cao, J Zhou, B Yang, VWC Chang, WW Nazaroff Building and Environment 99, 73-81, 2016 | 45 | 2016 |
Effect of thermal transient on human thermal comfort in temporarily occupied space in winter–A case study in Tianjin ZJ Yu, B Yang, N Zhu Building and Environment 93, 27-33, 2015 | 43 | 2015 |
Three-dimension numerical simulation of a hybrid fresh air and re-circulated air diffuser for decoupled ventilation strategy B Yang, C Sekhar Building and Environment 42 (5), 1975-1982, 2007 | 42 | 2007 |
Cooling load calculation methods in spaces with stratified air: a brief review and numerical investigation Y Cheng, B Yang, Z Lin, J Yang, J Jia, Z Du Energy and Buildings 165, 47-55, 2018 | 35 | 2018 |
Thermal comfort in primary school classrooms: A case study under subarctic climate area of Sweden B Yang, T Olofsson, F Wang, W Lu Building and Environment 135, 237-245, 2018 | 33 | 2018 |
Thermal comfort and energy performance of personal comfort systems (PCS): a systematic review and meta- analysis W Song, Z Zhang, Z Chen, F Wang, B Yang Building and Environment 256, 111747, 2022 | 32 | 2022 |