Metrological management of the high dc resistance scale at INRIM
F Galliana, PP Capra, E Gasparotto
Measurement 42 (2), 314-321, 2009
322009
The electrical DC resistance scale from 100 k/spl Omega/to 1 T/spl Omega/at IEN
F Galliana, G Boella
IEEE Transactions on Instrumentation and Measurement 49 (5), 959-963, 2000
312000
Inter-laboratories comparison at 100 GΩ and 1 TΩ level to evaluate the traceability transfer from INRIM in the field of high dc resistance
F Galliana, PP Capra, E Gasparotto
Measurement 45 (3), 615-621, 2012
232012
Evaluation of two alternative methods to calibrate ultrahigh value resistors at INRIM
F Galliana, PP Capra, E Gasparotto
IEEE Transactions on Instrumentation and Measurement 60 (3), 965-970, 2010
232010
Traceable technique to calibrate clamp meters in AC current from 100 to 1500 A
F Galliana, PP Capra
IEEE Transactions on Instrumentation and Measurement 61 (9), 2512-2518, 2012
192012
Analysis of the voltage coefficient of high value standard resistors
G Boella, F Galliana
Measurement 41 (1), 1-9, 2008
182008
Analysis of a national comparison in the field of electrical low dc resistance
F Galliana, E Gasparotto
Measurement 52, 64-70, 2014
152014
A traceable technique to calibrate dc current shunts and resistors in the range from 10 μΩ to 10 mΩ
F Galliana, PP Capra, E Gasparotto
Measurement 46 (4), 1630-1640, 2013
152013
Report of the Italian inter-laboratories comparison of high dc resistance on the calibration of a 10MΩ and a 1GΩ resistors
F Galliana, PP Capra, E Gasparotto
Measurement 42 (10), 1532-1540, 2009
152009
Calibration of standard resistors in the field 10 MΩ÷ 1 TΩ by means of a digital multimeter
F Galliana, G Boella, PP Capra
Proceedings of IMEKO TC 4, 191-195, 1998
141998
Accurate comparison between INRIM and a secondary calibration laboratory using a top-class multifunction electrical calibrator
F Galliana, M Lanzillotti
Measurement 103, 353-360, 2017
132017
Final report on supplementary comparison EURAMET. EM-S32: Comparison of resistance standards at 1 TΩ and 100 TΩ
B Jeckelmann, JHN van der Beek, PP Capra, P Chrobok, L Cirneanu, ...
Metrologia 50 (1A), 01008-01008, 2013
122013
1 Ω and 10 kΩ high precision transportable setup to calibrate multifunction electrical instruments
PP Capra, F Galliana
Measurement 82, 367-374, 2016
112016
Compatibility of measurement results within measurement systems using hypotheses tests
S D’Emilio, F Galliana, E Arri, G Iuculano
8th, Metrologie 97, 589-594, 1997
101997
Automated precision DC voltage fixed ratios divider
F Galliana, PP Capra, R Cerri, M Lanzillotti
Measurement 122, 291-296, 2018
92018
Comparison of different methods for the calibration of standard resistors in the range 10 MΩ÷ 1 GΩ
G Boella, F Galliana
Proc. of 8th, 457-461, 1997
81997
Hamon-GuardedNetwork to Increase the Accuracy of the Transfer of the Resistance Unit up to 1at INRIM
PP Capra, F Galliana
IEEE Transactions on Instrumentation and Measurement 58 (8), 2726-2729, 2009
72009
A temperature variable high accuracy 10 kΩ resistor
P Capra, C Cassiago, F Galliana, M Astrua
Metrol. Meas. Syst 16, 183-191, 2009
72009
Measurement comparisons: A tool to guarantee the reliability of measurement systems and of high-tech industry
F Galliana
IEEE Instrumentation & Measurement Magazine 22 (2), 62-66, 2019
62019
The strategic role of inter-laboratory comparison among international institutions to assure confidence: report of the INRIM and the European spatial agency comparison on …
F Galliana, M Del Moro
MAPAN 33, 77-82, 2018
62018