Professor Tom Joyce
Professor Tom Joyce
Verified email at ncl.ac.uk
Title
Cited by
Cited by
Year
Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear
DJ Langton, SS Jameson, TJ Joyce, NJ Hallab, S Natu, AVF Nargol
The Journal of bone and joint surgery. British volume 92 (1), 38-46, 2010
7282010
Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear
DJ Langton, TJ Joyce, SS Jameson, J Lord, M Van Orsouw, JP Holland, ...
The Journal of bone and joint surgery. British volume 93 (2), 164-171, 2011
4232011
Accelerating failure rate of the ASR total hip replacement
DJ Langton, SS Jameson, TJ Joyce, JN Gandhi, R Sidaginamale, ...
The Journal of bone and joint surgery. British volume 93 (8), 1011-1016, 2011
3942011
The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip
DJ Langton, SS Jameson, TJ Joyce, J Webb, AVF Nargol
The Journal of bone and joint surgery. British volume 90 (9), 1143-1151, 2008
3472008
Taper junction failure in large-diameter metal-on-metal bearings
DJ Langton, R Sidaginamale, JK Lord, AVF Nargol, TJ Joyce
Bone & joint research 1 (4), 56-63, 2012
2592012
Blood metal ion concentrations after hip resurfacing arthroplasty: a comparative study of articular surface replacement and Birmingham Hip Resurfacing arthroplasties
DJ Langton, AP Sprowson, TJ Joyce, M Reed, I Carluke, P Partington, ...
The Journal of bone and joint surgery. British volume 91 (10), 1287-1295, 2009
2472009
Blood metal ion testing is an effective screening tool to identify poorly performing metal-on-metal bearing surfaces
RP Sidaginamale, TJ Joyce, JK Lord, R Jefferson, PG Blain, AVF Nargol, ...
Bone & joint research 2 (5), 84-95, 2013
932013
The clinical implications of elevated blood metal ion concentrations in asymptomatic patients with MoM hip resurfacings: a cohort study
DJ Langton, RP Sidaginamale, TJ Joyce, S Natu, P Blain, RD Jefferson, ...
BMJ open 3 (3), 2013
902013
Volumetric wear assessment of failed metal-on-metal hip resurfacing prostheses
JK Lord, DJ Langton, AVF Nargol, TJ Joyce
Wear 272 (1), 79-87, 2011
752011
Statistical wear analysis of PA-6/UHMWPE alloy, UHMWPE and PA-6
CZ Liu, LQ Ren, J Tong, TJ Joyce, SM Green, RD Arnell
Wear 249 (1-2), 31-36, 2001
732001
A multi‐directional wear screening device and preliminary results of UHMWPE articulating against stainless steel
TJ Joyce, D Monk, SC Scholes, A Unsworth
Bio-medical materials and engineering 10 (3, 4), 241-249, 2000
592000
Reducing metal ion release following hip resurfacing arthroplasty
DJ Langton, TJ Joyce, N Mangat, J Lord, M Van Orsouw, K De Smet, ...
Orthopedic Clinics 42 (2), 169-180, 2011
492011
Examination of failed ex vivo metal-on-metal metatarsophalangeal prosthesis and comparison with theoretically determined lubrication regimes
TJ Joyce
Wear 263 (7-12), 1050-1054, 2007
462007
Shorter, rough trunnion surfaces are associated with higher taper wear rates than longer, smooth trunnion surfaces in a contemporary large head metal‐on‐metal total hip …
TM Brock, R Sidaginamale, S Rushton, AVF Nargol, JG Bowsher, ...
Journal of Orthopaedic Research 33 (12), 1868-1874, 2015
452015
Analysis of the in-vivo failure of the adhesive interlayer for a DLC coated articulating metatarsophalangeal joint
R Hauert, G Thorwarth, U Müller, M Stiefel, CV Falub, K Thorwarth, ...
Diamond and related materials 25, 34-39, 2012
442012
The design of a finger wear simulator and preliminary results
TJ Joyce, A Unsworth
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2000
402000
Challenges associated with using bovine serum in wear testing orthopaedic biopolymers
AP Harsha, TJ Joyce
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2011
382011
Retrospective cohort study of the performance of the Pinnacle metal on metal (MoM) total hip replacement: a single-centre investigation in combination with the findings of a …
DJ Langton, RP Sidaginamale, P Avery, S Waller, G Tank, J Lord, T Joyce, ...
BMJ open 6 (4), 2016
372016
A comparison of ex vivo and in vitro Sutter metacarpophalangeal prostheses
TJ Joyce, RH Milner, A Unsworth
Journal of Hand Surgery 28 (1), 86-91, 2003
342003
A literature review of" failures" of the Swanson finger prosthesis in the metacarpophalangeal joint
TJ Joyce, A Unsworth
Hand surgery 7 (01), 139-146, 2002
342002
The system can't perform the operation now. Try again later.
Articles 1–20