Follow
Jingjuan Feng
Jingjuan Feng
Verified email at berkeley.edu
Title
Cited by
Cited by
Year
Model predictive control of radiant slab systems with evaporative cooling sources
JD Feng, F Chuang, F Borrelli, F Bauman
Energy and Buildings 87, 199-210, 2015
1642015
Cooling load differences between radiant and air systems
JD Feng, S Schiavon, F Bauman
Energy and buildings 65, 310-321, 2013
1262013
Experimental comparison of zone cooling load between radiant and air systems
JD Feng, F Bauman, S Schiavon
Energy and Buildings 84, 152-159, 2014
642014
New method for the design of radiant floor cooling systems with solar radiation
JD Feng, S Schiavon, F Bauman
Energy and Buildings 125, 9-18, 2016
572016
Design and control of hydronic radiant cooling systems
J Feng
University of California, Berkeley, 2014
252014
Cooling load calculations for radiant systems: are they the same traditional methods?
F Bauman, JD Feng, S Schiavon
ASHRAE Journal, 2013
182013
Impact of Solar Heat Gain on Radiant Floor Cooling System Design
JD Feng, S Schiavon, F Bauman
102013
Influence of supply air temperature on underfloor air distribution (UFAD) system energy performance
T Webster, KH Lee, F Bauman, S Schiavon, T Hoyt, J Feng, A Daly
Proceedings of SimBuild 4 (1), 466-473, 2010
102010
Granularity transformation of qualitative criterion, orthogonality of qualitative mapping system, and pattern recognition
J Feng, J Feng
Granular Computing, 2006 IEEE International Conference on, 211-216, 2006
102006
Critical review of water based radiant cooling system design methods
JD Feng, F Bauman, S Schiavon
Indoor Air 2014, 2014
92014
Advanced Integrated Systems Technology Development: Personal Comfort Systems and Radiant Slab Systems
F Bauman, H Zhang, E Arens, P Raftery, C Karmann, JD Feng, Y Zhai, ...
82015
Impacts of Static Pressure Reset on VAV System Air Leakage, Fan Power, and Thermal Energy.
M Liu, J Feng, Z Wang, L Wu, K Zheng, X Pang
ASHRAE Transactions 116 (1), 2010
72010
Qualitative mapping, inner product transformation of qualitative criterion, artificial neuron and pattern recognition
J Feng, Q Mao, G Xu, J Feng
Multimedia, Seventh IEEE International Symposium on, 6 pp., 2005
62005
Advanced Integrated Systems Technology Development
F Bauman, T Webster, H Zhang, E Arens, D Lehrer, D Dickerhoff, JD Feng, ...
52013
Lessons learned in modeling Underfloor Air Distribution system
KH Lee, S Schiavon, T Webster, F Bauman, J Feng, T Hoyt
Center for the Built Environment, 2011
52011
Economizer control using mixed air enthalpy
J Feng, M Liu, X Pang
4*2011
Evaluation of cooling performance of thermally activated building system with evaporative cooling source for typical United States climates
J Feng, F Bauman
32013
Development of guidelines for Modeling Underfloor Air Distribution (UFAD) Systems in EnergyPlus, eQUEST, and EnergyPro for use in California non-residential Building Energy …
T Webster, KH Lee, T Hoyt, JD Feng, A Daly, S Schiavon, F Bauman
32011
Impacts of Static Pressure Reset on VAV System Air Leakage, Fan Power and Thermal Energy-Part 1: Theoretical Model and Simulation
M Liu, J Feng, Z Wang, L Wu, K Zheng, X Pang
32011
Qualitative Mapping and Artificial Neuron
J Feng, G Xu, Z Dong, J Feng
Neural Networks and Brain, 2005. ICNN&B'05. International Conference on 1 …, 2005
22005
The system can't perform the operation now. Try again later.
Articles 1–20