Follow
Pekka Saarinen
Pekka Saarinen
researcher, Turku University of Applied Sciences
Verified email at ttl.fi
Title
Cited by
Cited by
Year
Chapter 13: "Resolution Enhancement Approaches" and all the problems and examples in: Fourier transforms in spectroscopy
J Kauppinen, J Partanen
Fourier transforms in spectroscopy, 2006
280*2006
Line-shape distortions in misaligned cube corner interferometers
J Kauppinen, P Saarinen
Applied optics 31 (1), 69-74, 1992
851992
Multicomponent analysis of FT-IR spectra
P Saarinen, J Kauppinen
Applied spectroscopy 45 (6), 953-963, 1991
801991
Different types of door-opening motions as contributing factors to containment failures in hospital isolation rooms
JW Tang, A Nicolle, J Pantelic, CA Klettner, R Su, P Kalliomaki, ...
PloS one 8 (6), e66663, 2013
772013
Airflow patterns through single hinged and sliding doors in hospital isolation rooms–Effect of ventilation, flow differential and passage
P Kalliomäki, P Saarinen, JW Tang, H Koskela
Building and Environment 107, 154-168, 2016
722016
Impact of heat load location and strength on air flow pattern with a passive chilled beam system
R Kosonen, P Saarinen, H Koskela, A Hole
Energy and Buildings 42 (1), 34-42, 2010
562010
Instrumental resolution considerations for Fourier transform infrared gas-phase spectroscopy
P Jaakkola, JD Tate, M Paakkunainen, J Kauppinen, P Saarinen
Applied spectroscopy 51 (8), 1159-1169, 1997
541997
Spectral line-shape distortions in Michelson interferometers due to off-focus radiation source
P Saarinen, J Kauppinen
Applied optics 31 (13), 2353-2359, 1992
541992
A method for long extrapolation of audio signals
I Kauppinen, J Kauppinen, P Saarinen
Journal of the Audio Engineering Society 49 (12), 1167-1180, 2001
522001
Large eddy simulation of air escape through a hospital isolation room single hinged doorway—Validation by using tracer gases and simulated smoke videos
PE Saarinen, P Kalliomäki, JW Tang, H Koskela
PloS one 10 (7), e0130667, 2015
402015
Thermal plumes of kitchen appliances: Cooking mode
R Kosonen, H Koskela, P Saarinen
Energy and buildings 38 (10), 1141-1148, 2006
382006
Airflow patterns through single hinged and sliding doors in hospital isolation rooms
P Kalliomäki, P Saarinen, JW Tang, H Koskela
International Journal of Ventilation 14 (2), 111-126, 2015
352015
Health effects of wind turbine noise and road traffic noise on people living near wind turbines
J Radun, H Maula, P Saarinen, J Keränen, R Alakoivu, V Hongisto
Renewable and Sustainable Energy Reviews 157, 112040, 2022
342022
New method for spectral line shape fitting and critique on the Voigt line shape model
PE Saarinen, JK Kauppinen, JO Partanen
Applied spectroscopy 49 (10), 1438-1453, 1995
341995
Thermal plumes of kitchen appliances: Idle mode
R Kosonen, H Koskela, P Saarinen
Energy and buildings 38 (9), 1130-1139, 2006
292006
On-line analysis of stack gas composition by a low resolution FT-IR gas analyzer
PT Jaakkola, TA Vahlman, AA Roos, PE Saarinen, JK Kauppinen
Water, Air, and Soil Pollution 101, 79-92, 1998
251998
Large-eddy simulation of the containment failure in isolation rooms with a sliding door—An experimental and modelling study
P Saarinen, P Kalliomäki, H Koskela, JW Tang
Building simulation 11, 585-596, 2018
232018
Indoor air-related symptoms and volatile organic compounds in materials and air in the hospital environment
P Rautiainen, M Hyttinen, J Ruokolainen, P Saarinen, J Timonen, ...
International Journal of Environmental Health Research 29 (5), 479-488, 2019
222019
Procedures for analyzing multicomponent FT-IR spectra for unknown mixtures of gases
J Kauppinen, P Saarinen
US Patent 5,313,406, 1994
201994
Annoyance of low-level tonal sounds–A penalty model
V Hongisto, P Saarinen, D Oliva
Applied Acoustics 145, 358-361, 2019
172019
The system can't perform the operation now. Try again later.
Articles 1–20