ICE decoupling technique for RF coil array designs Y Li, Z Xie, Y Pang, D Vigneron, X Zhang Medical Physics 38, 4086, 2011 | 140 | 2011 |
Flexible transceiver array for ultrahigh field human MR imaging B Wu, X Zhang, C Wang, Y Li, Y Pang, J Lu, D Xu, S Majumdar, SJ Nelson, ... Magnetic Resonance in Medicine, 2012 | 71 | 2012 |
A practical multinuclear transceiver volume coil for in vivo MRI/MRS at 7 T C Wang, Y Li, B Wu, D Xu, SJ Nelson, DB Vigneron, X Zhang Magnetic resonance imaging, 2011 | 44 | 2011 |
Resonant mode reduction in radiofrequency volume coils for ultrahigh field magnetic resonance imaging Y Pang, Z Xie, Y Li, D Xu, D Vigneron, X Zhang Materials 4 (8), 1333-1344, 2011 | 25 | 2011 |
Investigation of multichannel phased array performance for fetal MR imaging on 1.5 T clinical MR system Y Li, Y Pang, D Vigneron, O Glenn, D Xu, X Zhang Quantitative imaging in medicine and surgery 1 (1), 24, 2011 | 25 | 2011 |
Image homogenization using pre-emphasis method for high field MRI Y Li, C Wang, B Yu, D Vigneron, W Chen, X Zhang Quantitative Imaging in Medicine and Surgery 3 (4), 217, 2013 | 24 | 2013 |
Advanced MR Imaging Technologies in Fetuses Y Li, X Zhang OMICS J Radiology 1, e113, 2012 | 20 | 2012 |
Planar Quadrature RF Transceiver Design Using Common-Mode Differential-Mode (CMDM) Transmission Line Method for 7T MR Imaging Y Li, B Yu, Y Pang, DB Vigneron, X Zhang PLOS ONE 8 (11), e80428, 2013 | 19 | 2013 |
An 8-channel RF coil array for carotid artery MR imaging in humans at 3 T X Hu, L Zhang, X Zhang, H Zhu, X Chen, Y Zhang, YC Chung, X Liu, ... Medical Physics 43 (4), 1897-1906, 2016 | 18 | 2016 |
Multi-Reception Strategy with Improved SNR for Multichannel MR Imaging B Wu, Y Li, C Wang, DB Vigneron, X Zhang PloS one 7 (8), e42237, 2012 | 15 | 2012 |
Parallel imaging performance investigation of an 8-channel common-mode differential-mode (CMDM) planar array for 7T MRI X Hu, X Chen, X Liu, H Zheng, Y Li, X Zhang Quantitative imaging in medicine and surgery 4 (1), 33, 2014 | 14 | 2014 |
Signal-to-Noise Ratio Improvement by Bi-2223 Surface RF Coil in 0.3 T MRI System Y Li, Y Guo, X Jiang Applied Superconductivity, IEEE Transactions on 20 (3), 818-821, 2010 | 9 | 2010 |
用于小动物脑磁共振成像及功能磁共振成像的正交微波传输带线圈设计 李烨, 蒋晓华 中国医学影像技术, 1485-1487, 2009 | 2 | 2009 |
Calculating Efficient Noise Resistance of RF Coils for Low Field MRI Systems Y Li, XH Jiang PIERS Online 3 (6), 879-882, 2007 | 2 | 2007 |
磁共振成像中涡流效应的仿真 马超, 褚旭, 李烨, 蒋晓华 清华大学学报 (自然科学版) 4, 001, 2007 | 1 | 2007 |
Parallel MRI performance evaluation of a novel 32 channel fetal array at 1.5T Ye Li, Yong Pang, Daniel Vigneron, Orit Glenn Proceedings of the 20th Annual Meeting of the ISMRM, Melbourne, Australia, 568, 2012 | | 2012 |