Follow
Tham Kwok Wai
Tham Kwok Wai
Associate Professor, Department of the Built Environment,National University of Singapore
Verified email at nus.edu.sg
Title
Cited by
Cited by
Year
How can airborne transmission of COVID-19 indoors be minimised?
L Morawska, JW Tang, W Bahnfleth, PM Bluyssen, A Boerstra, ...
Environment international 142, 105832, 2020
8232020
Thermal comfort evaluation of naturally ventilated public housing in Singapore
NH Wong, H Feriadi, PY Lim, KW Tham, C Sekhar, KW Cheong
Building and Environment 37 (12), 1267-1277, 2002
2672002
Airflow dynamics of human jets: sneezing and breathing-potential sources of infectious aerosols
JW Tang, AD Nicolle, CA Klettner, J Pantelic, L Wang, AB Suhaimi, ...
PloS one 8 (4), e59970, 2013
2522013
Indoor air quality and its effects on humans—A review of challenges and developments in the last 30 years
KW Tham
Energy and Buildings 130, 637-650, 2016
2442016
Effects of temperature and outdoor air supply rate on the performance of call center operators in the tropics
KW Tham
Indoor air 14 (7), 119-125, 2004
219*2004
Development of the ASHRAE global thermal comfort database II
VF Ličina, T Cheung, H Zhang, R De Dear, T Parkinson, E Arens, C Chun, ...
Building and Environment 142, 502-512, 2018
2162018
Thermal comfort study of an air-conditioned lecture theatre in the tropics
KWD Cheong, E Djunaedy, YL Chua, KW Tham, SC Sekhar, NH Wong, ...
Building and environment 38 (1), 63-73, 2003
1642003
Behavior-a Link between Function and Structure in Design
JS Gero, KW Tham, HS Lee
IFIP Transactions B-applications in Technology 4, 193-220, 1992
1471992
Findings of personalized ventilation studies in a hot and humid climate
SC Sekhar, N Gong, KW Tham, KW Cheong, AK Melikov, DP Wyon, ...
HVAC&R Research 11 (4), 603-620, 2005
126*2005
The effect of ventilation strategies of child care centers on indoor air quality and respiratory health of children in Singapore
MS Zuraimi, KW Tham, FT Chew, PL Ooi
Indoor air 17 (4), 317-327, 2007
1222007
Room air temperature affects occupants’ physiology, perceptions and mental alertness
KW Tham, HC Willem
Building and Environment 45 (1), 40-44, 2010
1212010
A comparative study of VOCs in Singapore and European office buildings
MS Zuraimi, CA Roulet, KW Tham, SC Sekhar, KWD Cheong, NH Wong, ...
Building and environment 41 (3), 316-329, 2006
1212006
Personalized ventilation as a control measure for airborne transmissible disease spread
J Pantelic, GN Sze-To, KW Tham, CYH Chao, YCM Khoo
Journal of the Royal Society Interface 6 (suppl_6), S715-S726, 2009
1182009
Experimental investigation of the human convective boundary layer in a quiescent indoor environment
D Licina, J Pantelic, A Melikov, C Sekhar, KW Tham
Building and Environment 75, 79-91, 2014
1172014
k-Shape clustering algorithm for building energy usage patterns analysis and forecasting model accuracy improvement
J Yang, C Ning, C Deb, F Zhang, D Cheong, SE Lee, C Sekhar, KW Tham
Energy and Buildings 146, 27-37, 2017
1102017
The acceptable air velocity range for local air movement in the tropics
N Gong, KW Tham, AK Melikov, DP Wyon, SC Sekhar, KW Cheong
Hvac&r Research 12 (4), 1065-1076, 2006
1092006
Clients’ assessment of architects’ performance in building delivery process: Evidence from Nigeria
LO Oyedele, KW Tham
Building and Environment 42 (5), 2090-2099, 2007
1052007
A paradigm shift to combat indoor respiratory infection
L Morawska, J Allen, W Bahnfleth, PM Bluyssen, A Boerstra, G Buonanno, ...
Science 372 (6543), 689-691, 2021
1032021
Associations between home dampness and presence of molds with asthma and allergic symptoms among young children in the tropics
KW Tham, MS Zuraimi, D Koh, FT Chew, PL Ooi
Pediatric Allergy and Immunology 18 (5), 418-424, 2007
1022007
Indoor air quality and its determinants in tropical child care centers
MS Zuraimi, KW Tham
Atmospheric Environment 42 (9), 2225-2239, 2008
942008
The system can't perform the operation now. Try again later.
Articles 1–20