Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses CC Hsu, CK Chao, JL Wang, SM Hou, YT Tsai, J Lin Journal of Orthopaedic Research 23 (4), 788-794, 2005 | 255 | 2005 |
Increasing bending strength and pullout strength in conical pedicle screws: biomechanical tests and finite element analyses CK Chao, CC Hsu, JL Wang, J Lin Clinical Spine Surgery 21 (2), 130-138, 2008 | 142 | 2008 |
Mechanical tests and finite element models for bone holding power of tibial locking screws SM Hou, CC Hsu, JL Wang, CK Chao, J Lin Clinical Biomechanics 19 (7), 738-745, 2004 | 75 | 2004 |
Biomechanical study of different fixation techniques for the treatment of sacroiliac joint injuries using finite element analyses and biomechanical tests CH Lee, CC Hsu, PY Huang Computers in biology and medicine 87, 250-257, 2017 | 68 | 2017 |
Biomechanical investigation into the structural design of porous additive manufactured cages using numerical and experimental approaches PI Tsai, CC Hsu, SY Chen, TH Wu, CC Huang Computers in Biology and Medicine 76, 14-23, 2016 | 66 | 2016 |
Simulation-based particle swarm optimization and mechanical validation of screw position and number for the fixation stability of a femoral locking compression plate CH Lee, KS Shih, CC Hsu, T Cho Medical Engineering & Physics 36 (1), 57-64, 2014 | 57 | 2014 |
Adjustable vertebral spacer for vertebral reconstruction WH Hsu, HC Hsu, CC Hsu, YH Tsai, KS Shih, LM Lu US Patent 8,034,111, 2011 | 53 | 2011 |
A biomechanical investigation of the effects of static fixation and dynamization after interlocking femoral nailing: a finite element study KS Shih, CC Hsu, TP Hsu Journal of Trauma and Acute Care Surgery 72 (2), E46-E53, 2012 | 48 | 2012 |
Increasing bending strength of tibial locking screws: mechanical tests and finite element analyses CK Chao, CC Hsu, JL Wang, J Lin Clinical Biomechanics 22 (1), 59-66, 2007 | 45 | 2007 |
Multiobjective optimization of tibial locking screw design using a genetic algorithm: evaluation of mechanical performance CC Hsu, CK Chao, JL Wang, J Lin Journal of Orthopaedic Research 24 (5), 908-916, 2006 | 41 | 2006 |
Biomechanical comparisons of different posterior instrumentation constructs after two-level ALIF: a finite element study CY Fan, CC Hsu, CK Chao, SC Lin, KH Chao Medical engineering & physics 32 (2), 203-211, 2010 | 37 | 2010 |
Comparison of multiple linear regression and artificial neural network in developing the objective functions of the orthopaedic screws CC Hsu, J Lin, CK Chao Computer methods and programs in biomedicine 104 (3), 341-348, 2011 | 29 | 2011 |
Notch sensitivity of titanium causing contradictory effects on locked nails and screws CC Hsu, A Yongyut, CK Chao, J Lin Medical engineering & physics 32 (5), 454-460, 2010 | 25 | 2010 |
Comparison of the bending performance of solid and cannulated spinal pedicle screws using finite element analyses and biomechanical tests KS Shih, CC Hsu, SM Hou, SC Yu, CK Liaw Medical engineering & physics 37 (9), 879-884, 2015 | 24 | 2015 |
Biomechanical analyses of static and dynamic fixation techniques of retrograde interlocking femoral nailing using nonlinear finite element methods KS Shih, CC Hsu, TP Hsu, SM Hou, CK Liaw Computer methods and programs in biomedicine 113 (2), 456-464, 2014 | 24 | 2014 |
A neurogenetic approach to a multiobjective design optimization of spinal pedicle screws CK Chao, J Lin, ST Putra, CC Hsu Journal of biomechanical engineering 132 (9), 2010 | 23 | 2010 |
Shape optimization for the subsidence resistance of an interbody device using simulation‐based genetic algorithms and experimental validation CC Hsu Journal of Orthopaedic Research 31 (7), 1158-1163, 2013 | 22 | 2013 |
The dynamic impact response of 3D-printed polymeric sandwich structures with lattice cores: Numerical and experimental investigation SY Jhou, CC Hsu, JC Yeh Polymers 13 (22), 4032, 2021 | 21 | 2021 |
Adjustable vertebral spacer for vertebral reconstruction WH Hsu, HC Hsu, CC Hsu, YH Tsai, KS Shih, LM Lu US Patent 8,372,151, 2013 | 20 | 2013 |
Parametric study on the interface pullout strength of the vertebral body replacement cage using FEM-based Taguchi methods WH Hsu, CK Chao, HC Hsu, J Lin, CC Hsu Medical engineering & physics 31 (3), 287-294, 2009 | 20 | 2009 |