Follow
Ching-Chi Hsu
Ching-Chi Hsu
Verified email at mail.ntust.edu.tw
Title
Cited by
Cited by
Year
Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses
CC Hsu, CK Chao, JL Wang, SM Hou, YT Tsai, J Lin
Journal of Orthopaedic Research 23 (4), 788-794, 2005
2552005
Increasing bending strength and pullout strength in conical pedicle screws: biomechanical tests and finite element analyses
CK Chao, CC Hsu, JL Wang, J Lin
Clinical Spine Surgery 21 (2), 130-138, 2008
1422008
Mechanical tests and finite element models for bone holding power of tibial locking screws
SM Hou, CC Hsu, JL Wang, CK Chao, J Lin
Clinical Biomechanics 19 (7), 738-745, 2004
752004
Biomechanical study of different fixation techniques for the treatment of sacroiliac joint injuries using finite element analyses and biomechanical tests
CH Lee, CC Hsu, PY Huang
Computers in biology and medicine 87, 250-257, 2017
682017
Biomechanical investigation into the structural design of porous additive manufactured cages using numerical and experimental approaches
PI Tsai, CC Hsu, SY Chen, TH Wu, CC Huang
Computers in Biology and Medicine 76, 14-23, 2016
662016
Simulation-based particle swarm optimization and mechanical validation of screw position and number for the fixation stability of a femoral locking compression plate
CH Lee, KS Shih, CC Hsu, T Cho
Medical Engineering & Physics 36 (1), 57-64, 2014
572014
Adjustable vertebral spacer for vertebral reconstruction
WH Hsu, HC Hsu, CC Hsu, YH Tsai, KS Shih, LM Lu
US Patent 8,034,111, 2011
532011
A biomechanical investigation of the effects of static fixation and dynamization after interlocking femoral nailing: a finite element study
KS Shih, CC Hsu, TP Hsu
Journal of Trauma and Acute Care Surgery 72 (2), E46-E53, 2012
482012
Increasing bending strength of tibial locking screws: mechanical tests and finite element analyses
CK Chao, CC Hsu, JL Wang, J Lin
Clinical Biomechanics 22 (1), 59-66, 2007
452007
Multiobjective optimization of tibial locking screw design using a genetic algorithm: evaluation of mechanical performance
CC Hsu, CK Chao, JL Wang, J Lin
Journal of Orthopaedic Research 24 (5), 908-916, 2006
412006
Biomechanical comparisons of different posterior instrumentation constructs after two-level ALIF: a finite element study
CY Fan, CC Hsu, CK Chao, SC Lin, KH Chao
Medical engineering & physics 32 (2), 203-211, 2010
372010
Comparison of multiple linear regression and artificial neural network in developing the objective functions of the orthopaedic screws
CC Hsu, J Lin, CK Chao
Computer methods and programs in biomedicine 104 (3), 341-348, 2011
292011
Notch sensitivity of titanium causing contradictory effects on locked nails and screws
CC Hsu, A Yongyut, CK Chao, J Lin
Medical engineering & physics 32 (5), 454-460, 2010
252010
Comparison of the bending performance of solid and cannulated spinal pedicle screws using finite element analyses and biomechanical tests
KS Shih, CC Hsu, SM Hou, SC Yu, CK Liaw
Medical engineering & physics 37 (9), 879-884, 2015
242015
Biomechanical analyses of static and dynamic fixation techniques of retrograde interlocking femoral nailing using nonlinear finite element methods
KS Shih, CC Hsu, TP Hsu, SM Hou, CK Liaw
Computer methods and programs in biomedicine 113 (2), 456-464, 2014
242014
A neurogenetic approach to a multiobjective design optimization of spinal pedicle screws
CK Chao, J Lin, ST Putra, CC Hsu
Journal of biomechanical engineering 132 (9), 2010
232010
Shape optimization for the subsidence resistance of an interbody device using simulation‐based genetic algorithms and experimental validation
CC Hsu
Journal of Orthopaedic Research 31 (7), 1158-1163, 2013
222013
The dynamic impact response of 3D-printed polymeric sandwich structures with lattice cores: Numerical and experimental investigation
SY Jhou, CC Hsu, JC Yeh
Polymers 13 (22), 4032, 2021
212021
Adjustable vertebral spacer for vertebral reconstruction
WH Hsu, HC Hsu, CC Hsu, YH Tsai, KS Shih, LM Lu
US Patent 8,372,151, 2013
202013
Parametric study on the interface pullout strength of the vertebral body replacement cage using FEM-based Taguchi methods
WH Hsu, CK Chao, HC Hsu, J Lin, CC Hsu
Medical engineering & physics 31 (3), 287-294, 2009
202009
The system can't perform the operation now. Try again later.