Prediction of dosimetric accuracy for VMAT plans using plan complexity parameters via machine learning T Ono, H Hirashima, H Iramina, N Mukumoto, Y Miyabe, M Nakamura, ... Medical Physics 46 (9), 3823-3832, 2019 | 53 | 2019 |
Improvement of prediction and classification performance for gamma passing rate by using plan complexity and dosiomics features H Hirashima, T Ono, M Nakamura, Y Miyabe, N Mukumoto, H Iramina, ... Radiotherapy and Oncology 153, 250-257, 2020 | 50 | 2020 |
Quantification of the kV X-ray imaging dose during real-time tumor tracking and from three-and four-dimensional cone-beam computed tomography in lung cancer patients using a … M Nakamura, Y Ishihara, Y Matsuo, Y Iizuka, N Ueki, H Iramina, ... Journal of radiation research 59 (2), 173-181, 2018 | 25 | 2018 |
The accuracy of extracted target motion trajectories in four-dimensional cone-beam computed tomography for lung cancer patients H Iramina, M Nakamura, Y Iizuka, T Mitsuyoshi, Y Matsuo, T Mizowaki, ... Radiotherapy and Oncology 121 (1), 46-51, 2016 | 17 | 2016 |
Treatment planning based on water density image generated using dual‐energy computed tomography for pancreatic cancer with contrast‐enhancing agent: phantom and clinical study S Ohira, M Yagi, H Iramina, T Karino, H Washio, Y Ueda, M Miyazaki, ... Medical Physics 45 (11), 5208-5217, 2018 | 12 | 2018 |
Metal artifact reduction by filter-based dual-energy cone-beam computed tomography on a bench-top micro-CBCT system: concept and demonstration H Iramina, T Hamaguchi, M Nakamura, T Mizowaki, I Kanno Journal of radiation research 59 (4), 511-520, 2018 | 12 | 2018 |
Dosiomic feature comparison between dose-calculation algorithms used for lung stereotactic body radiation therapy T Adachi, M Nakamura, R Kakino, H Hirashima, H Iramina, Y Tsuruta, ... Radiological Physics and Technology 15 (1), 63-71, 2022 | 8 | 2022 |
Photoneutron-induced damage reduction for cardiac implantable electronic devices using neutron-shielding sheets in high-energy X-ray radiotherapy: A phantom study R Kakino, M Nakamura, N Hu, H Iramina, H Tanaka, Y Sakurai, ... Physica Medica 89, 151-159, 2021 | 7 | 2021 |
Actual delivered dose calculation on intra-irradiation cone-beam computed tomography images: a phantom study H Iramina, M Nakamura, T Mizowaki Physics in Medicine & Biology 66 (1), 015007, 2021 | 7 | 2021 |
Direct measurement and correction of both megavoltage and kilovoltage scattered x‐rays for orthogonal kilovoltage imaging subsystems with dual flat panel detectors H Iramina, M Nakamura, T Mizowaki Journal of Applied Clinical Medical Physics 21 (9), 143-154, 2020 | 7 | 2020 |
Quality assurance of non-coplanar, volumetric-modulated arc therapy employing a C-arm linear accelerator, featuring continuous patient couch rotation H Hirashima, M Nakamura, Y Miyabe, N Mukumoto, T Ono, H Iramina, ... Radiation Oncology 14, 1-10, 2019 | 7 | 2019 |
Quantification and correction of the scattered X-rays from a megavoltage photon beam to a linac-mounted kilovoltage imaging subsystem H Iramina, M Nakamura, Y Miyabe, N Mukumoto, T Ono, H Hirashima, ... BJR| Open 2 (1), 20190048, 2020 | 6 | 2020 |
A survey towards standardization of dosimetric verification in intensity-modulated radiation therapy M Nakamura, H Iramina, M Takamiya, T Ono, M Akimoto, N Mukumoto, ... Igaku Butsuri: Nihon Igaku Butsuri Gakkai Kikanshi= Japanese Journal of …, 2014 | 6 | 2014 |
Performance evaluation of a newly developed three-dimensional model-based global-to-local registration in prostate cancer M Nakamura, M Nakao, H Hirashima, H Iramina, T Mizowaki Journal of Radiation Research 60 (5), 595-602, 2019 | 5 | 2019 |
Effective atomic number measurement with energy-resolved computed tomography using two-dimensional “transXend” detector H Iramina, M Nakamura, T Mizowaki, I Kanno International Journal of Medical Physics, Clinical Engineering and Radiation …, 2018 | 5 | 2018 |
Potential utility of cone‐beam CT‐guided adaptive radiotherapy under end‐exhalation breath‐hold conditions for pancreatic cancer A Ogawa, M Nakamura, H Iramina, M Yoshimura, T Mizowaki Journal of Applied Clinical Medical Physics 24 (2), e13827, 2023 | 4 | 2023 |
Image quality evaluation of intra‐irradiation cone‐beam computed tomography acquired during one‐and two‐arc prostate volumetric‐modulated arc therapy delivery: A phantom study H Iramina, A Kitamura, M Nakamura, T Mizowaki Journal of Applied Clinical Medical Physics 21 (12), 231-239, 2020 | 4 | 2020 |
Filter-based energy-resolved X-ray computed tomography with a clinical imager TH Tsai, T Hamaguchi, H Iramina, M Nakamura, I Kanno Journal of Nuclear Science and Technology 56 (2), 210-220, 2019 | 4 | 2019 |
A novel method for dose distribution registration using fiducial marks made by a megavoltage beam in film dosimetry for intensity-modulated radiation therapy quality assurance S Nakayama, H Monzen, Y Oonishi, R Mizote, H Iramina, S Kaneshige, ... Physica Medica 31 (4), 414-419, 2015 | 4 | 2015 |
Automatic measurement of beam‐positioning accuracy at off‐isocenter positions T Ono, T Kido, M Nakamura, H Iramina, R Kakino, T Mizowaki Journal of Applied Clinical Medical Physics 24 (3), e13844, 2023 | 2 | 2023 |