Follow
pawel wargocki
pawel wargocki
Verified email at byg.dtu.dk
Title
Cited by
Cited by
Year
The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome (SBS) symptoms and productivity
P Wargocki, DP Wyon, J Sundell, G Clausen, PO Fanger
Indoor air 10 (4), 222-236, 2000
1294*2000
Literature survey on how different factors influence human comfort in indoor environments
M Frontczak, P Wargocki
Building and environment 46 (4), 922-937, 2011
10552011
The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome (SBS) symptoms and productivity
P Wargocki, DP Wyon, J Sundell, G Clausen, PO Fanger
Indoor air 10 (4), 222-236, 2000
932*2000
The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome (SBS) symptoms and productivity
P Wargocki, DP Wyon, J Sundell, G Clausen, PO Fanger
Indoor air 10 (4), 222-236, 2000
932*2000
How can airborne transmission of COVID-19 indoors be minimised?
L Morawska, JW Tang, W Bahnfleth, PM Bluyssen, A Boerstra, ...
Environment international 142, 105832, 2020
8232020
Perceived air quality, sick building syndrome (SBS) symptoms and productivity in an office with two different pollution loads
P Wargocki, DP Wyon, YK Baik, G Clausen, PO Fanger
Indoor air 9 (3), 165-179, 1999
6451999
Quantitative relationships between occupant satisfaction and satisfaction aspects of indoor environmental quality and building design
M Frontczak, S Schiavon, J Goins, E Arens, H Zhang, P Wargocki
Indoor air 22 (2), 119-131, 2012
5492012
The effects of moderately raised classroom temperatures and classroom ventilation rate on the performance of schoolwork by children (RP-1257)
P Wargocki, DP Wyon
Hvac&R Research 13 (2), 193-220, 2007
3982007
Quantitative measurement of productivity loss due to thermal discomfort
L Lan, P Wargocki, Z Lian
Energy and Buildings 43 (5), 1057-1062, 2011
3652011
Effects of thermal discomfort in an office on perceived air quality, SBS symptoms, physiological responses, and human performance
L Lan, P Wargocki, DP Wyon, Z Lian
Indoor air 21 (5), 376-390, 2011
2982011
Effects of pollution from personal computers on perceived air quality, SBS symptoms and productivity in offices
Z Bako-Biro, P Wargocki, CJ Weschler, PO Fanger
Indoor air 14 (3), 178-187, 2004
2652004
Providing better thermal and air quality conditions in school classrooms would be cost-effective
P Wargocki, DP Wyon
Building and Environment 59, 581-589, 2013
2472013
Can commonly-used fan-driven air cleaning technologies improve indoor air quality? A literature review
Y Zhang, J Mo, Y Li, J Sundell, P Wargocki, J Zhang, JC Little, R Corsi, ...
Atmospheric Environment 45 (26), 4329-4343, 2011
2322011
Questionnaire survey on factors influencing comfort with indoor environmental quality in Danish housing
M Frontczak, RV Andersen, P Wargocki
Building and Environment 50, 56-64, 2012
2252012
Productivity is affected by the air quality in offices
P Wargocki, DP Wyon, PO Fanger
Proceedings of Healthy Buildings 1 (1), 635-40, 2000
2222000
Effects of exposure to carbon dioxide and bioeffluents on perceived air quality, self‐assessed acute health symptoms, and cognitive performance
X Zhang, P Wargocki, Z Lian, C Thyregod
Indoor air 27 (1), 47-64, 2017
2182017
Research report on effects of HVAC on student performance
P Wargocki, DP Wyon
ASHRAE journal 48 (10), 22, 2006
1972006
Dismantling myths on the airborne transmission of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2)
JW Tang, WP Bahnfleth, PM Bluyssen, G Buonanno, JL Jimenez, ...
Journal of Hospital Infection 110, 89-96, 2021
1922021
Ten questions concerning green buildings and indoor air quality
A Steinemann, P Wargocki, B Rismanchi
Building and Environment 112, 351-358, 2017
1812017
The effects of outdoor air supply rate and supply air filter condition in classrooms on the performance of schoolwork by children (RP-1257)
P Wargocki, DP Wyon
Hvac&r Research 13 (2), 165-191, 2007
1802007
The system can't perform the operation now. Try again later.
Articles 1–20